Aug 17, 2026
68
NDS2i and NDS5i
Key
LP=Left Program Button
RP=Right Program Button
ViSN Mode
-
1+LP: WiFi setup.
-
4+LP: Toggle Mode: WiFi mode or Essential mode.
-
Press and hold LP: Setup screen panel.
-
Press and hold RP: Function confirmation.
-
Press and hold 2+4: Toggle 12-hour/24-hour format.
Essential Mode
-
Press and hold LP: Setup screen panel.
-
4+LP: Toggle Mode: WiFi mode or Essential mode.
-
1+RP: Master code programming.
-
2+RP: Fingerprint programming.
-
3+RP: Delete all fingerprints.
-
4+RP: Toggle dual entry mode.
-
2+3+RP: Toggle anti-pry alarm.
-
3+4+RP: Toggle open door over-time alarm.
-
Press and hold 2+4: Toggle 12-hour/24-hour format.